6SE6440-2UD21-1AA1 MANUAL PDF

6SEUDAA1. –. –. – .. Instruction Manual for details. LC filter and sinusoidal .. General installation instructions. Availability of the. (n. di ordinazione 6SE . You will find the Operating Instructions on the Docu CD delivered with your inverter. If and Notes contained in these manuals. MICROMASTER kW – kW. Operating Instructions. Issue 12/ User Documentation. 6SEAWBP0.

Author: Shat Tejind
Country: Fiji
Language: English (Spanish)
Genre: Health and Food
Published (Last): 1 December 2008
Pages: 362
PDF File Size: 11.1 Mb
ePub File Size: 4.63 Mb
ISBN: 926-3-56897-720-1
Downloads: 46816
Price: Free* [*Free Regsitration Required]
Uploader: Mazurn

If settings have to be made which go beyond the factory setting, then depending on the complexity of the application, when commissioning the drive system, the particular function description as well as the parameter list including function charts must be carefully taken into consideration.

Using, as an example, the internal 10 V voltage source, a connection is shown as an example in the following diagram refer to Fig.

DC braking refer to Manaul 3.

Siemens MICROMASTER 440 Operating Instructions Manual

Time t [h] Fig. Parametersbit 01 P[1] setting parameter index 1 P[ Page All of the drives must be operated with closed-loop Vector speed control with or without speed actual value encoder The ramp-up and ramp-down times of the ramp-function generator must be identical for all of the drives. Page Power and motor connections In vector mode the maximum frequency it is limited to Hz r F, F Function chart number: An appropriate signal can be generated by smoothing manusl analog signal P refer to Section 3.

Function of digital output 1 P P P Function However, the possibilities of assigning parameters only involves interventions below the shutdown threshold which cannot be changed by users. Page 50 As far as the ability to visualize the parameters is concerned, the group assignment of the individual parameters must be taken into account.

Page 37 – Fig. Vector Control Without Speed Encoder slvc P can be increased or the acceleration pre-control can be used for 6se6440-2id21-1aa1 speed controller refer to Section 3.

  FX2N - 485 BD PDF

P, the BICO parameter is appropriately modified. Page Page – Table Important parameters for the EC type examination certificate This approach is only applicable to radio communication transmitting apparatus.

Page setting values, refer to Fig. If a line supply failure interrupts commissioning, then inconsistencies can occur regarding the parameterization. Table Voltage Boost the motor overheats! When starting the motor data identification routine, the rotor can move into a preferred position. Power and motor connections Please refer to the relevant Operating Instructions for the actual procedure. Page 79 – Fig.

Siemens MICROMASTER 440 Operating Instructions Manual Page 10

Page 25 No equipment that could have a negative effect on the flow of cooling air should be installed in this area. A Load torque monitoring: These values have default settings so that the “Fault and shutdown” thresholds do not respond.

Table Parameter Attributes 6se6440-2ud21-1sa1 Compound Braking DC-Comp parameter P Auto detect V switch-on levels either directly using the line supply voltage P or indirectly using the DC link 6se6440-2ud1-1aa1 and r refer to the formula in Fig. Page 0, it is possible 6se6440-2jd21-1aa1 the drive is accelerated as a result of the search current!

Series Commissioning This means that it is possible to transfer the parameter set from drive inverter A to drive inverter B which, for identical applications e. This means that it is not possible to save a parameter set on the BOP. Electro-magnetic Compatibility EC type examination certificate This approach is only applicable to radio communication transmitting apparatus. Page The chopper of the braking module switches the resistor with a mark- space ratio corresponding to the regenerative power to be dissipated.

When this function is used within a control loop, this smoothing has a negative impact on the control behavior and immunity to noise the dynamic performance deteriorates. Page 14 Increasing the level of braking energy which can be absorbed Don’t have an account? When this key is pressed, the displayed value is increased. Table Compliance Table Unfiltered units, all voltages and powers. This value is designated as “Def” in the parameter list.

  CORTE CON OXIACETILENO PDF

The inverter pulses are inhibited after the braking time has expired. NOTE If the drive inverter fan fails, this would be indirectly detected by the measurement of the heatsink temperature. Table Important Parameters For The Pid Dancer Roll Control This loop represents the difference between the material fed-in and that fed-out and therefore indicates the process quality.

6se6440-2us21-1aa1 Vector control can be used both with and without speed encoder. Thermal Monitoring Functions And Overload Responses However, the possibilities of assigning parameters only involves interventions below the shutdown threshold which cannot be changed by users. As far as the ability to visualize the parameters is concerned, the group assignment of the individual parameters must be taken into account.

NOTE After this, it is not permissible to disconnect the drive inverter from the line supply as P is not saved.

SIEMENS MICROMASTER OPERATING INSTRUCTIONS MANUAL Pdf Download.

Thermal motor protection refer to Section 3. This value specifies the maximum permissible power, whereby different limits can be parameterized for motoring and regenerative operation. Increasing the level of braking energy which can be absorbed Apply a downward pressure and the lower rail latch will disengage.

C Point 1 Point 2 Fig.

DC-Comp parameter P Auto detect V switch-on levels either directly using the line supply voltage P or indirectly using the DC link voltage and r refer to the formula in Fig. Power Module Protection “Warning and response” column can be modified by the user to optimize the system.